Dimensions with packaging (H x W x D) [mm (in.)] | 730 mm x 770 mm x 1150 mm (28.74 in. x 30.31 in. x 45.28 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] | 438 mm x 483 mm x 985 mm (17.24 in. x 19.02 in. x 38.78 in.)
(including mounting brackets) |
Weight without packaging [kg (lb)] | 98.1 kg (216.31 lb) (including two MPUs and filler panels) |
Weight without packaging (full configuration) [kg (lb)] | 163.6 kg (360.74 lb) |
Weight with packaging [kg (lb)] | 142 kg (313.11 lb) |
Cabinet installation standards | A812 |
Chassis height [U] | 9.8 U |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | N+M |
Power supply mode | DC |
Number of power modules | 6 |
Redundant power supply | - Dual-input power supply system: N+1 backup is recommended.
- Single-input power supply system: N+1 backup
Dual-input power supply is recommended to ensure reliability. |
Rated input voltage [V] | -48 V/-60 V |
Input voltage range [V] | -40 V to -72 V |
Maximum input current [A] | 58.5 A for the voltage of -40 V |
Maximum output power [W] | - In 5+1 backup mode: 2200 W x 5 = 11000 W
- In 6+0 backup mode: 2200 W x 6 = 13200 W
|
Certification | - Compliance with safety standards
- Compliance with EMC standards
- Compliance with environment and environmental protection standards
|
Redundant fans | Fan modules work in hot standby mode. At the normal temperature
range, the system can operate properly for a short time after a
single fan module fails. You are advised to replace the faulty fan
module immediately. |
Heat dissipation mode | Heat dissipation using fans |
Airflow direction | Front-to-back airflow |
Availability | 0.9999971695 |
MTBF [year] | 34.93 year |
MTTR [hour] | 1 hour |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) (When the altitude is between 1800 m and 5000
m (5906 ft. and 16404 ft.), the highest operating temperature
reduces by 1°C (1.8°F) every time the altitude increases by 220 m
(722 ft.).) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, noncondensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |